In this video we take a look at a few issues in the 10 dollar 101 before we get into a complete repair. This way we know better where we stand at and can now plan our attack.
#59 Yaesu FT-101 Series Part 1 Preliminary Test In this video we look at the 10 dollar flea market Yaesu FT-101. I installed the missing boards and components and we give the radio a over look to see where it is electrically. Inside we find the Mylar capacitors on the audio board have heavy moister damage. We also discover the wrong audio board was previously installed.
In this video we troubleshoot a very fine piece of vintage CB test gear. Inside the unit we find that the 3 74161 program divider chip failed in a cascade format. We also find that IC307 took out a resistor. After replacing the failed components we getthe unit back up and running.
mauroh message with the ICSP connector on the banggood tester http://www.eevblog.com/forum/testgear/$20-lcr-esr-transistor-checker-project/msg854124/#msg854124
Just a short video on last couple of weeks. Been very busy here with work, wedding and shop time. DIY transistor tester issue Noise generator Fluke 8520A Browning R27 S23
In this video we go through this old HP 410a VTVM and replace all the paper capacitors. We also have to fabricate a new DC probe since the original is damaged.
#51 Fluke 8520A How far does this rabbit hole go? Part 1
In part 1of this video we tackle a few tantalum capacitors that has gone dead short. We also have to replace a faulty LM340T-12 regulator after checking the voltage rails. Just how many problems does this "Working EBay Find" have? I am at a stand still till I do more research...
In the first picture we have to replave C238 due it is shorted. We also had to replace R256 and 257
Here we finf C450 is also shorted. This was dragging the +15 volt rail down.
We find that U704 has a dead short from input to output. This is a LM340T-12
When you boot the 8520A on it is showing a voltage on the display. This should show"000"
If you hit 2-wire or 4-wire to test the Ohm setting you will get Error 1. This means high voltage when selecting ohms scale
After repairing the voltage rails we still have the error 1. But if you pull J19 we get no errors. But ofcourse the meter does not function.
And again with J19 removed we can go into ohms mode.
So with J19 removed the error goes away. The unit does not function but it looks like we are closer to the problem. We still have to trouble shoot error code 01. Err01 HV - High voltage present with ohms function selected.